Fire-Lite

MS-9200UDLS

The Fire-Lite MS-9200UDLS is an addressable fire alarm control panel supporting 1 SLC loop with up to 318 devices. One of the most popular mid-size panels in the US market.

13 manuals51 trouble codesModels: MS-9200UDLS, MS-9200, MS-9200E, MS-9200UDLSE

Manuals

Manuals That Reference This Model (42)
ECC-50/100 and ECC-50/100EInstallationOperationsProgramming2014ACC-25/50InstallationOperationsProgramming2010ES-200X SeriesDatasheet2023ACM-8RFInstallationProgramming2001CHG-120FInstallationOperations2001DACT-UDInstallationOperationsProgramming2005ACM-16ATF and ACM-32AFInstallationOperationsProgramming2001DIM-485InstallationWiring Diagram1995CHG-75InstallationOperationsProgramming2001UDACT-FInstallationOperationsProgramming2001BG-12LXDatasheet2012ECC-50/100Datasheet2018Fire Command 25/50InstallationOperationsProgramming1997Device Compatibility Document2022PS-Tools for the 198 Pt Addr PanelUser Guide2010MMF-302-6Installation2008LCD-40InstallationOperationsProgramming1999ANN-LCDatasheet2015ANN-I/ODatasheet2018IPDACTInstallationOperations2007CMF-300-6Datasheet2015W-BG12LX and W-BG12LXSPDatasheet2018W-GATEDatasheet2018ECC-FFTDatasheet2015Document ChartManual2017VisorALARM PLUS 2UInstallation2007ANN-RLYDatasheet2018LCD-40 Series Software Change Procedure1998UDACT-FInstallationOperationsProgramming1997Transmitter Connection to FACPInstallation2006PS-Tools for the 636 Pt Addr PanelUser Guide2010ECC-50/100C Command CtrDatasheet2015IPDACT-2/2UD CommunicatorDatasheet2014W-MMF & W-CRFDatasheet2018MMF-300-10Installation2008LCD-40InstallationOperations1996ES-200XDatasheet2018CRF-300-6InstallationProgramming2008PK-9200InstallationProgramming1997PRN-7Installation2015Seismic Certification KitsBrochure2014FCPS-24FDatasheet1998

Trouble Codes

View all 51
24 HOUR ABNORMAL TESThe automatic 24-hour communicator test failed or was attempted while the system was in an off-normal state.AC_FAILThe control panel has lost its primary AC power source.AC LOSSThe panel has detected that the primary AC power has dropped too low or failed, causing the AC POWER indicator to extinguish and the system trouble indicator to activate.ACS FAULTCommunication failure with an ACS Annunciator device.ACTIVE SUPERVISORYSupervisory operation indicates a condition that is similar to an alarm but typically monitors system components like sprinkler valves or pressure switches to ensure they are in their normal state.ALARM SILENCEDThis condition indicates that the Notification Appliance Circuits (NACs) have been silenced by pressing the Alarm Silence key while an alarm condition exists.Battery FaultA general fault related to the system standby batteries.CHARGER FAULTThe internal battery charging circuit is not operating within normal parameters.COMM FAULT 1 / COMM FAULT 2Indicates a communication failure between the panel's internal Digital Alarm Communicator/Transmitter (DACT) and the central station.COMM FAULT 1The communicator failed to successfully transmit a report to the central station using line 1.

Specifications

SLC Loops
1
Panel Type
Addressable
NAC Circuits
4 Class B / 2 Class A
Total Points
318 (LiteSpeed) / 198 (CLIP)
Points/Loop
318 (LiteSpeed) / 198 (CLIP)
Battery (Ah)
7-26
Annunciator
Yes