Edwards EST
EST3
SLC Loops: 2 (per chassis) | NAC Circuits: 4 (per 3-LBUS module) | Points: 500 (per chassis)
Edwards EST
EST4
SLC Loops: 10 | NAC Circuits: 4 (per module) | Points: 2,500
Edwards EST
iO1000
SLC Loops: 4 | NAC Circuits: 4 Class B / 2 Class A | Points: 1,000
Edwards EST
iO64
SLC Loops: 1 | NAC Circuits: 2 Class B / 1 Class A | Points: 64
ESSER
FlexES
SLC Loops: 1-18 (model dependent) | NAC Circuits: 4 | Points: 127-2,286
Fenwal
FENWALNET 6000
SLC Loops: 1 | NAC Circuits: 4 | Points: 255
Fire-Lite
MS-5024
SLC Loops: N/A (Conventional) | NAC Circuits: 2 | Battery: 7-17
Fire-Lite
MS-9200UDLS
SLC Loops: 1 | NAC Circuits: 4 Class B / 2 Class A | Points: 318 (LiteSpeed) / 198 (CLIP)
Fire-Lite
MS-9600
SLC Loops: 1 (expandable to 2) | NAC Circuits: 4 Class B / 2 Class A | Points: 636 (LiteSpeed) / 396 (CLIP)
Honeywell
VISTA-128FBP
SLC Loops: N/A (V-Plex Polling Loop) | NAC Circuits: 2 | Battery: 4-14
Kidde
Aegis 2.0
SLC Loops: N/A (Conventional) | NAC Circuits: 3 | Battery: 12-68
Kidde
FX-10
SLC Loops: N/A (Conventional) | NAC Circuits: 4 Class B / 2 Class A | Battery: 7-24
Kidde
FX-5
SLC Loops: N/A (Conventional) | NAC Circuits: 2 Class B / 1 Class A | Battery: 7-24
Notifier
INSPIRE N16
SLC Loops: 1-3 (N16e) / 1-10 (N16x) | NAC Circuits: 4 Class A or B | Points: 954 (N16e) / 3,180 (N16x)
Notifier
NFS-320
SLC Loops: 1 | NAC Circuits: 4 Class B / 2 Class A | Points: 318
Notifier
NFS2-3030
SLC Loops: 1-10 | NAC Circuits: 4 Class B / 2 Class A | Points: 3,180
Notifier
NFS2-640
SLC Loops: 1 (expandable to 2) | NAC Circuits: 4 Class B / 2 Class A | Points: 318 / 636 (dual loop)
Notifier
NFW2-100
SLC Loops: 1 | NAC Circuits: 4 Class B / 2 Class A | Points: 198
Siemens
MXL
SLC Loops: 1-4 (ALD) | NAC Circuits: 2 Class A or B | Points: 240
Silent Knight
5820XL
SLC Loops: 1 (expandable to 4) | NAC Circuits: 6 Class B / 3 Class A | Points: 396 (SK) / 508 (SD Hochiki)
Silent Knight
SK-5207
SLC Loops: N/A (Conventional) | NAC Circuits: 4 Style Y | Battery: 17-34
Silent Knight
SK-6820
SLC Loops: 1 (expandable to 4) | NAC Circuits: 6 Class B / 3 Class A | Points: 1,110 (SK) / 635 (SD Hochiki)
Simplex
4010ES
SLC Loops: 1 (expandable) | NAC Circuits: 4 Class A or B | Points: 1,000
Simplex
4100ES
SLC Loops: 2 (expandable) | NAC Circuits: 3 Class A or B | Points: 2,500
Key Specs
SLC LoopsNAC CircuitsPoints/LoopBatteryNetwork NodesAnnunciator
Spec Comparison

Use the specs table to compare loop capacity, NAC circuits, and communication options when specifying a replacement or upgrade panel.

Recommended SupplierSponsored

Fire Alarm Parts for Old and New Systems

  • Panels, detectors, modules and signals
  • 50+ brands, current and legacy
  • Order by 3 pm ET, ships same day
  • 90-day warranty on every part
Shop Fire Alarm Parts
Can't find what you need?

Resource Center

QuestionsPanelsTrouble CodesPanel SpecsNFPA 72-2025

Legal

Privacy PolicyTerms of UseDisclaimerDMCA

Cookie Preferences

Cookie Policy

Company

About UsBlogGlossaryContact Us

© FACP Manuals LLC. All rights reserved.

Built by Will

FACP Manuals Logo
FACPManuals
Resource CenterTools
Ask AI
Sign In
Ask AI
Sign In