Siemens

MXL

The Siemens MXL is a large intelligent fire alarm control panel widely deployed in commercial and institutional settings.

24 manuals19 trouble codesModels: MXL, MXL-V, MXL-IQ, MXLV

Specifications

SLC Loops
1-4 (ALD)
Panel Type
Addressable
NAC Circuits
2 Class A or B
Total Points
240
Points/Loop
60
Battery (Ah)
7-100
Annunciator
Yes

Manuals

MXL-IQ
InstallationOperations
MXL and MXLV
InstallationOperations
OMM-2 for MXLV
Installation
MXL Device Interface Module
Datasheet2020
MXL-IQ
InstallationOperations
MXL Multi-Line Keyboard/Display
Operating Instructions
FCL-MXLPLATE
Installation
MXL v5.1
Technical Reference2021
MXL Marine Fire Detection System
Manual
MXL/MXLV Upgrade Kits
Installation
MXL OPC Interface v5.0
Technical Reference2020
MXL Migration Strategies
Brochure2020
MXL-IQ Migration Hardware
Datasheet2020
TRI-B6M and TRI-B6MC for FireFinder XLS and MXL
Datasheet2012
MXL System Migration
Brochure2011
5128 for MXL
Installation
RDM-MXL
Installation
MXL OPC Interface v4.0
Technical Reference2019
SEG-FLASH KIT for MXL
Installation
MLE-6 for MXL
Installation
TBM-2 for MXLV System
Installation
RCM-1 for MXL and MXLV
Datasheet2011
MKB-1 for MXL
Installation
MXL Phased Migration
Brochure2020
Manuals That Reference This Model (6)

Trouble Codes

View all 19
AC Fail or BrownoutPrimary AC power is missing or below the brownout level; the System is running on battery backup.AC VOLTAGE = X VOLTSDisplay of the current AC input voltage to the system power supply.ALARM NOT ALL ACKNOWLEDGED YETThe system prevents acknowledging supervisories or troubles while an unacknowledged alarm exists.BATT CHG CUR = XX.X AMPSDisplay of the current being used to charge the system batteries.BATTERY VOLTAGE = X.X VOLTSDisplay of the current system battery voltage during a power test.NN:MMM-DDD [custom message] ACK [device type] IN ALRAn initiating device has entered the alarm state, indicating a fire or emergency condition.NN:MMM-DDD [custom message] ACK [device type] IN SECA security-related device has been activated, indicating a potential security breach or monitoring event.NN:MMM-DDD [custom message] ACK [device type] IN SUPA supervisory condition has been detected, typically indicating that a monitored fire protection system component is in an abnormal state.GROUND FAULT IS MINUSThe system has detected a negative ground fault on the field wiring.GROUND FAULT IS OKThe system ground fault test has passed and no ground faults are currently detected.