Silent Knight

5820XL

The Silent Knight 5820XL (IFP-1000) is an addressable fire alarm panel supporting 1 SLC loop. Widely used in small to medium commercial applications.

20 manuals24 trouble codesModels: 5820XL, SK-5820XL, 5820, IFP-1000, IFP-1000VIP

Specifications

SLC Loops
1 (expandable to 4)
Panel Type
Addressable
NAC Circuits
6 Class B / 3 Class A
Total Points
396 (SK) / 508 (SD Hochiki)
Points/Loop
99 (SK) / 127 (SD Hochiki)
Battery (Ah)
7-35
Annunciator
Yes

Manuals

Manuals That Reference This Model (135)
6820Datasheet2022SK-PHOTO-W SeriesDatasheet20186820EVSDatasheet20225496Datasheet2017Addressable Pull StationsDatasheet20155860InstallationQuick Start2014EVS-INT50WInstallation20155880Datasheet2018IDP-Photo DetectorsDatasheet20086820EVSDatasheet20205660InstallationOperationsProgramming2016IDP-Heat DetectorsDatasheet2008EVS-50W AmplifierDatasheet2017ECS-RCUDatasheet20156820Datasheet2018IDP-Control-6 ModuleDatasheetEVS-RVMInstallation2013ECS-125WDatasheet2014IDP-Control ModuleDatasheetIDP-Zone-6 ModuleDatasheet2009EVS-50W AmplifierDatasheet2018IFP-FFT Telephone SystemDatasheet2015IDP-Pduct Duct DetectorsDatasheet2008EVS-100WDatasheet2018IDP-ISODatasheet2015EVS-LOCInstallation20175496Datasheet2013SK-MINIMONDatasheet2017EVS-VCMInstallation2013ECS-50WDatasheet2014IDP-6AB & SSB501 BasesDatasheet2009SSB224BI Isolator BaseDatasheet20095860 and 5860RDatasheet2017EVS-RCU Command UnitDatasheet2015EVS-125W AmplifierDatasheet2018SK-RELAY-6Datasheet2017IFP-100VIP Voice PanelDatasheet2006SD500-ARMDatasheet2017IPGSM-4GDatasheet20135895XLInstallationOperations2018IDP-Acclimate DetectorDatasheet2008SK-CONTROLDatasheet2017SK-PULL-SA and SK-PULL-DADatasheet2017B200SRDatasheet2015SK-FFTDatasheet2019SD500-AIM and SD500-MIMDatasheet2016RA-100Datasheet2014SD500-ARMQuick StartIDP-Minimon MonitorDatasheetVIP-50Datasheet2010IDP-Monitor-10 ModuleDatasheetSK-CONTROL-6Datasheet2017EVS-INT50WDatasheet2015SK-DUCTDatasheet2017RA-1000Datasheet2014SD505-6SBInstallation2008IDP-Monitor ModuleDatasheet2009SK-MON-10Datasheet2017SK-MONITOR-2Datasheet2017SSB224RB Relay BaseDatasheet2009IDP-Zone Interface ModuleDatasheetIDP-Beam DetectorsDatasheet20085895XLDatasheet2018SD505-6IBDatasheet2010Farenhyt SeriesBrochure2011EVS-LOC Operator ConsoleDatasheet2017SD500-AIM and SD500-MIMDatasheet2008SD500-LEDDatasheet2001SK-Relaymon-2Datasheet2015IDP-RelayDatasheet2015IDP-Relay-6 Relay ModuleDatasheetIDP-Photo, IDP-Photo-T and IDP-PhotoRDatasheet2015SD500-SDMDatasheet20175815XLDatasheet20185880 SeriesDatasheet2015IDP-AcclimateDatasheet2015SK-ZONEDatasheet2017SK-ISODatasheet2017SD500-LEDDatasheet2013SSB501BHT Sounder BaseDatasheet2006SK-F485CDatasheet2017IDP-MonitorDatasheet2015IDP-Monitor-2 ModuleDatasheetIDP-IonDatasheet2013SD500-ANMDatasheet2017B224BIDatasheet20135760 and 5670InstallationOperations2016IDP-Iso Isolator ModuleDatasheet2009SD500-ARMDatasheet2010IDP-Control-6Datasheet2015IDP-Ion Smoke DetectorDatasheet2008IDP-FIRE-CODatasheet2015IDP-Monitor-10Datasheet2013ECS-DUAL50WDatasheet2014IDP-MinimonDatasheet2015EVS-125W AmplifierDatasheet20175824Datasheet2019IDP-Pull-SA and IDP-Pull-DADatasheet2013IDP-Monitor-2Datasheet2015IDP-Relay Relay ModuleDatasheet5865-3 and 5865-4Datasheet2017SD500-ANMDatasheet2004IDP-ControlDatasheet20155883Datasheet2017SK-FFTDatasheet2013IFPN-NIONDatasheet2006SD505-DUCTRDatasheet2011IDP-BeamDatasheet2015ECS-RPUDatasheet2015SK-MONITORDatasheet2017SK-ZONE-6Datasheet2017SK-F485CInstallation2012IFPN-ROUTMB and IFPN-4WRMBDatasheet2006SD500-LIMDatasheet2011PLEX-1 and PLEX-2Datasheet2004IDP-RELAYMON-2Datasheet2015IFP-NETBrochure2004IDP-Zone-6Datasheet2015ECS-INT50WDatasheet2015SK-RELAYDatasheet2017SSDNR and SSDNRWDatasheet2009SD500-LIMDatasheet2017EVS-CE4Installation2013SK-IP-2 and SK-IP-2UDDatasheet2014IFP-Net-3Datasheet2013IFP-NETULDatasheet2006VIP-125Datasheet2011IDP-ZoneDatasheet2015IDP-Relay-6Datasheet2015SD505-ADHDatasheet2001SD505-DUCTDatasheet2011SK-F485CDatasheet20125815XLDatasheet2013B224RBDatasheet2013B224BIDatasheet2017

Trouble Codes

View all 24
System Power (Flashes)The panel has lost primary AC power and is running on battery backup.Auxiliary Power TroubleA fault has been detected on the auxiliary power output circuit.BATTERY LOWThe system has detected that the standby battery voltage is below the acceptable threshold, indicating the batteries are depleted or failing to hold a charge.Battery voltage lowThe system has detected that the battery voltage is below the required threshold for reliable operation, typically less than 85% of its rating.DBL ADDRAn address has been assigned to more than one detector on the SLC loop.Detector troubleA smoke or heat detector is reporting a fault condition to the panel.Point disabledA point or circuit has been manually deactivated, preventing it from initiating or responding to alarms.GROUND FAULTAn earth ground fault occurs when the panel senses an unexpected flow of current from one or more of its terminals to the earth connection (Terminal 2).MissingSLC devices are not being recognized by the control panel, indicating a communication failure with a programmed device.Notification troubleA fault (open or short) has been detected on a Notification Appliance Circuit (NAC).

Related Questions