Fire-Lite

MS-9600

The Fire-Lite MS-9600 is a large addressable fire alarm panel supporting up to 2 SLC loops. Commonly used in larger commercial and institutional buildings.

7 manuals18 trouble codesModels: MS-9600, MS-9600LS, MS-9600E, MS-9600UDLS

Specifications

SLC Loops
1 (expandable to 2)
Panel Type
Addressable
NAC Circuits
4 Class B / 2 Class A
Total Points
636 (LiteSpeed) / 396 (CLIP)
Points/Loop
318 (LiteSpeed) / 198 (CLIP)
Battery (Ah)
7-120
Annunciator
Yes

Manuals

Manuals That Reference This Model (33)
ECC-50/100 and ECC-50/100EInstallationOperationsProgramming2014ACC-25/50InstallationOperationsProgramming2010ACM-8RFInstallationProgramming2001CHG-120FInstallationOperations2001DACT-UDInstallationOperationsProgramming2005UDACT-FInstallationOperationsProgramming2001ACM-16ATF and ACM-32AFInstallationOperationsProgramming2001CHG-75InstallationOperationsProgramming2001BG-12LXDatasheet2012Device Compatibility DocumentCompatibility Chart2022Fire SolutionsBrochure2018MMF-302-6Installation2008Document ChartManual2017ANN-I/ODatasheet2018ECC-50/100Datasheet2018VisorALARM PLUS 2UInstallation2007MMF-300-10Installation2008ECC-FFTDatasheet2015PS-Tools for the 50 Pt Addr PanelUser Guide2010IPDACTInstallationOperations2007IPDACT-2/2UD CommunicatorDatasheet2014PS-Tools for the 198 Pt Addr PanelUser Guide2010ECC-50/100C Command CtrDatasheet2015PRN-7Installation2015W-MMF & W-CRFDatasheet2018Central Station TransmitterInstallation2006OSI-RI-FLDatasheet2020W-GATEDatasheet2018W-BG12LX and W-BG12LXSPDatasheet2018PS-Tools for the 636 Pt Addr PanelUser Guide2010PK-9600UDDatasheet2001CMF-300-6Datasheet2015CRF-300-6InstallationProgramming2008

Trouble Codes

View all 18
AC LOSSThe control panel has lost its primary AC power supply and is currently operating on standby batteries.AC PowerThe control panel has lost its primary 120VAC or 240VAC power source.ACTIVE SUPERVISORYA condition indicating a state that needs attention but is not an alarm, such as a sprinkler valve tamper condition.ALARM SILENCEDThis condition indicates that the notification appliance circuits (NACs) have been manually turned off by pressing the Alarm Silence key while an alarm condition is still active.AUTO TEST FAILA smoke detector failed its automatic functional test performed by the panel every two hours.Battery FaultThe system has detected an issue with the standby batteries or their connection.Charger FaultThe internal battery charging circuit is not functioning correctly.DISABLIndicates that a zone, NAC, detector, or module has been temporarily disabled in programming by the user.Duplicate AddressThe system has detected more than one device sharing the same SLC address.EARTH FAULTA ground fault condition indicating zero impedance between the Fire Alarm Control Panel and ground.

Related Questions