A NAC trouble on the FX-5 is typically caused by a wiring fault, a programming mismatch, or the circuit being manually disabled. First, check the NAC Trouble...
The Simplex 4010ES supports four on-board notification appliance circuits (NAC1 through NAC4) (Page 64) [1]. NAC Specifications: Each circuit is rated for 3 A...
The MS-9600 provides four Style Y (Class B) or two Style Z (Class A) notification appliance circuits (NACs) at terminal TB4. These circuits are supervised and...
To perform a walk test on the Silent Knight 5820XL, navigate to the System Tests menu to choose between a reporting or non-reporting test. This process...
The Silent Knight 5820XL features six programmable Flexput circuits that can be configured as Notification Appliance Circuits (NACs), providing 3.0 A per...
The MS-9200UDLS features four onboard Notification Appliance Circuits (NACs) that provide 24 VDC nominal special application power (Page 15) [1]. Each circuit...
The NFS-320 features four built-in Notification Appliance Circuits (NACs) that can be configured for Class A (Style Z) or Class B (Style Y) operation (Page 25)...
The NFS2-640 features four onboard Notification Appliance Circuits (NACs) rated at 1.5 A each (Page 2) [1]. These 24 VDC circuits are supervised and...
Each NAC on the AEGIS 2.0 is independently configurable for Pre-Release and Releasing (post-release) conditions via the system configuration menu (Page 21)...
To convert FX-10 NAC circuits to Class A, you must pair the existing Class B circuits. The FX-10 supports up to 2 Class A NACs by converting pairs of its 4...
The Kidde FX-5 conventional fire alarm control panel requires a 4.7 kΩ end-of-line resistor (EOLR) for standard Initiating Device Circuits (IDCs) [1]. For IDCs...
To determine if your load exceeds FX-10 ratings, you must verify that the total current draw is within panel limits and that the voltage drop does not exceed...
To program NAC circuits on the FX-10, you must access the panel programming menu and assign specific values to the NAC Type option for each circuit. 1. Enter...
To configure the NFW2-100 NACs for Class A (Style Z) wiring, you must reorient the NACKEY card at jumper JP6. Note that switching to Class A reduces the...
The iO1000 is Class A Ready and does not require an expansion card for Class A wiring (Page 6) [1]. To configure this, you must program the NACs in pairs (one...